The effect of cement restrictors on the occlusion of the humeral canal:

An in vitro comparative study of 2 devices

Received 25 November 1998; accepted 1 March 1999.

Abstract 

An in vitro study investigated the efficacy of cement restrictor devices on cement containment and penetration within the humerus. Eight pairs of preserved humeri were prepared using advanced cementing technique followed by insertion of 1 of 2 cement restrictors. Low-viscosity cement was injected followed by sham humeral stern insertion. Each speciment was sectioned into transverse 10-mm slices. Slices were photographed and digitized to quantify the cement/stem and canal cross-sectional area. Cement penetration was determined from the ratio of cement area to canal area. A significant increase in cement penetration was observed among slices from distal to proximal for both restrictors (P = .02). There was no significant difference in cement penetration, leakage, or migration between restrictors. Five of the 8 specimens migrated, with means of 21.5 ± 25.0 mm and 24.0 ± 36.0 mm for the polyethylene and silicone restrictors. Leakage or migration resulted in a significant decrease in cement penetration with the polyethylene restrictors (P = .001). In the silicone restrictor group, migration resulted in decreased cement penetration (P = .04). When using advanced cementing techniques, intramedullary restrictors allow improved cement penetration; however, they do not ensure cement containment.

cementing, plugging, advanced technique, elbow, humerus

No full text is available. To read the body of this article, please view the PDF online.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Funds were received from the Lawson Research Institute Foundation in support of the research material described in this article. Implants used in the study were provided free of charge from Dow Corning Wright and Howmedica.

PII: S0883-5403(00)91389-5

The Journal of Arthroplasty
Volume 15, Issue 1 , Pages 113-119, January 2000