The Journal of Arthroplasty
Volume 22, Issue 1 , Pages 14-19 , January 2007

The Significance of Metal Staining on Alumina Femoral Heads in Total Hip Arthroplasty

  • B. Sonny Bal, MD, MBA

      Affiliations

    • Department of Orthopaedic Surgery, University of Missouri, Columbia, Missouri
    • Corresponding Author InformationReprint requests: B. Sonny Bal, MD, MBA, Department of Orthopaedic Surgery, University of Missouri, MC213, DC053.00, One Hospital Drive, Columbia, MO 65212.
  • ,
  • Mohamed N. Rahaman, PhD

      Affiliations

    • Department of Materials Science and Engineering, University of Missouri, Rolla, Missouri
  • ,
  • Thomas Aleto, MD

      Affiliations

    • Department of Orthopaedic Surgery, University of Missouri, Columbia, Missouri
  • ,
  • F. Scott Miller, PhD

      Affiliations

    • Department of Materials Science and Engineering, University of Missouri, Rolla, Missouri
  • ,
  • Francesco Traina, MD

      Affiliations

    • Rizzoli Orthopaedic Institute, Bologna, Italy
  • ,
  • Aldo Toni, MD

      Affiliations

    • Rizzoli Orthopaedic Institute, Bologna, Italy

Received 5 August 2005 ,Accepted 20 February 2006.

References 

  1. Urban JA, Garvin KL, Boese CK, et al. Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results. J Bone Joint Surg Am. 2001;83-A:1688
  2. Oonishi H, Takayaka Y, Clarke IC, et al. Comparative wear studies of 28 mm ceramic and metal total hip implants over a 2-7 year period. J Long Term Eff Med Implants. 1992;2:37
  3. Hamadouche M, Boutin P, Daussange J, et al. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002;84-A:69
  4. Oonishi H, Clarke IC, Williams PA, et al. Characterization of steady-state wear in all-alumina THR to 20 mc. Key Engineering Materials. 2002;218-220:587.
  5. Lancaster JG, Dowson D, Isaac GH, et al. The wear of ultrahigh molecular weight polyethylene sliding on metallic and ceramic counterfaces representative of current femoral surfaces in joint replacement. Proc Inst Mech Eng [H]. 1997;211:17
  6. Yoo JJ, Kim HJ, Kim YM. Damage of an alumina-on-alumina bearing surface from a difficult reduction of a total hip arthroplasty. A report of three cases. J Bone Joint Surg Am. 2004;86-A:376
  7. Luchetti WT, Copley LA, Vresilovic EJ, et al. Drain entrapment and titanium to ceramic head deposition: two unique complications following closed reduction of a dislocated total hip arthroplasty. J Arthroplasty. 1998;13:713
  8. Skinner HB. Ceramic bearing surfaces. Clin Orthop Relat Res. 1999;83
  9. Willmann G. Ceramic femoral head retrieval data. Clin Orthop Relat Res. 2000;22
  10. Kim YH, Ritchie A, Hardaker C. Surface roughness of ceramic femoral heads after in vivo transfer of metal: correlation to polyethylene wear. J Bone Joint Surg Am. 2005;87:577
  11. Walter WL, Insley GM, Walter WK, et al. Edge loading in third generation alumina ceramic-on-ceramic bearings: stripe wear. J Arthroplasty. 2004;19:402
  12. Simon JA, Dayan AJ, Ergas E, et al. Catastrophic failure of the acetabular component in a ceramic-polyethylene bearing total hip arthroplasty. J Arthroplasty. 1998;13:108
  13. Boehler M, Knahr K, Plenk H, et al. Long-term results of uncemented alumina acetabular implants. J Bone Joint Surg Br. 1994;76:53
  14. Hasegawa M, Ohashi T, Tani T. Poor outcome of 44 cemented total hip arthroplasties with alumina ceramic heads: clinical evaluation and retrieval analysis after 10-16 years. Acta Orthop Scand. 2001;72:449
  15. Mahoney OM, Dimon JH. Unsatisfactory results with a ceramic total hip prosthesis. [see comment] J Bone Joint Surg Am. 1990;72:663
  16. Winter M, Griss P, Scheller G, et al. Ten- to 14-year results of a ceramic hip prosthesis. Clin Orthop Relat Res. 1992;73
  17. Wirganowicz PZ, Thomas BJ. Massive osteolysis after ceramic on ceramic total hip arthroplasty. A case report. [see comment] Clin Orthop Relat Res. 1997;100
  18. Yoon TR, Rowe SM, Jung ST, et al. Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces. [see comment] J Bone Joint Surg Am. 1998;80:1459
  19. Dearnley PA. A review of metallic, ceramic and surface-treated metals used for bearing surfaces in human joint replacements. Proc Inst Mech Eng [H]. 1999;213:107
  20. Clarke IC, Campbell PA, Mishra AK. Debris-mediated osteolysis—a cascade phenomenon involving motion, wear, particulates, macrophage induction and bone lysis. In:  St. John KR editors. Particulate debris from medical implants. Philadelphia (Pa): ASTM; 1992;p. 7
  21. Nasser S, Campbell PA, Kilgus D, et al. Cementless total joint arthroplasty prostheses with titanium-alloy articular surfaces. A human retrieval analysis. Clin Orthop. 1990;171
  22. Nevelos J, Ingham E, Doyle C, et al. Microseparation of the centers of alumina-alumina artificial hip joints during simulator testing produces clinically relevant wear rates and patterns. [see comment] J Arthroplasty. 2000;15:793
  23. Thomsen M, Breusch SJ. Mechanical strength of used ceramic femoral heads. Hip Int. 2003;13:107
  24. Davidson JA, Poggie RA, Mishra AK. Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris. Biomed Mater Eng. 1994;4:213
  25. Mishra AK, Davidson JA. Zirconia/zirconium: a new abrasion-resistant material for othopaedic applications. J Mater Technol. 1993;8:16
  26. Bragdon CR, Jasty M, Kawate K, et al. Wear of retrieved cemented polyethylene acetabula with alumina femoral heads. J Arthroplasty. 1997;12:119
  27. DellaValle AG, Doty S, Gradl G, et al. Wear of a highly cross-linked polyethylene liner associated with metallic deposition on a ceramic femoral head. J Arthroplasty. 2004;19:532
  28. Jasty M, Bragdon CR, Lee K, et al. Surface damage to cobalt-chrome femoral head prostheses. [see comment] J Bone Joint Surg Br. 1994;76:73

 No benefits or funds were received in support of the study.

PII: S0883-5403(06)00254-3

doi: 10.1016/j.arth.2006.02.155

The Journal of Arthroplasty
Volume 22, Issue 1 , Pages 14-19 , January 2007