The Journal of Arthroplasty
Volume 24, Issue 8 , Pages 1146-1151 , December 2009

Long-Term Results of Cemented Total Hip Arthroplasty for Dysplasia, With Structural Autograft Fixed With Poly-l-Lactic Acid Screws

  • Koji Goto, MD, PhD

      Affiliations

    • Department of Orthopaedic Surgery, Faculty of Medicine, Kyoto University, Shogoin, Kawahara-cho 54, Sakyo-ku, Kyoto, Japan
    • Corresponding Author InformationReprint requests: Koji Goto, MD, PhD, Department of Orthopaedic Surgery, Faculty of Medicine, Kyoto University Shogoin, Kawahara-cho 54, Sakyo-ku, Kyoto 606-8507, Japan.
  • ,
  • Haruhiko Akiyama, MD, PhD

      Affiliations

    • Department of Orthopaedic Surgery, Faculty of Medicine, Kyoto University, Shogoin, Kawahara-cho 54, Sakyo-ku, Kyoto, Japan
  • ,
  • Keiichi Kawanabe, MD, PhD

      Affiliations

    • Department of Orthopaedic Surgery, Kobe City Medical Center General Hospital
  • ,
  • Kazutaka So, MD, PhD

      Affiliations

    • Department of Orthopaedic Surgery, Faculty of Medicine, Kyoto University, Shogoin, Kawahara-cho 54, Sakyo-ku, Kyoto, Japan
  • ,
  • Takeshi Morimoto, MD, PhD

      Affiliations

    • Center for Medical Education, Kyoto University Graduate School of Medicine, Konoe-cho, Yoshida, Sakyo-ku, Kyoto, Japan
  • ,
  • Takashi Nakamura, MD, PhD

      Affiliations

    • Department of Orthopaedic Surgery, Faculty of Medicine, Kyoto University, Shogoin, Kawahara-cho 54, Sakyo-ku, Kyoto, Japan

Received 14 January 2009 ,Accepted 20 April 2009.

References 

  1. Böstman O, Pihlajamäki H, Partio E, et al. Clinical biocompatibility and degradation of polylevolactide screws in the ankle. Clin Orthop Relat Res. 1995;320:101
  2. Bucholz R, Henry S, Henley M. Fixation with bioabsorbable screws for the treatment of fractures of the ankle. J Bone Joint Surg Am. 1994;76:319
  3. Yamamuro T, Matsusue Y, Uchida A, et al. Bioabsorbable osteosynthetic implants of ultra high strength poly-l-lactide. A clinical study. Int Orthop. 1994;18:332
  4. Hasegawa Y, Sakano S, Kawabe K. Ectopic bone formation around the poly-l-lactide screw head in rotational acetabular osteotomy for hip dysplasia. J Orthop Sci. 2004;9:551
  5. Crowe J, Mani V, Ranawat C. Total hip replacement in congenital dislocation and dysplasia of the hip. J Bone Joint Surg Am. 1979;61:15
  6. Wolfgang G. Femoral head autografting with total hip arthroplasty for lateral acetabular dysplasia. A 12-year experience. Clin Orthop Relat Res. 1990;255:173
  7. Sugano N, Nishii T, Nakata K, et al. Polyethylene sockets and alumina ceramic heads in cemented total hip arthroplasty. A ten-year study. J Bone Joint Surg Br. 1995;77:548
  8. Mibe J, Imakiire A, Watanabe T, et al. Results of total hip arthroplasty with bone graft and support ring for protrusio acetabuli in rheumatoid arthritis. J Orthop Sci. 2005;10:8
  9. DeLee J, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20
  10. Hodgkinson J, Shelley P, Wroblewski B. The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop Relat Res. 1998;228:105
  11. Goto K, Kawanabe K, Akiyama H, et al. Clinical and radiological evaluation of revision hip arthroplasty using the cement-in-cement technique. J Bone Joint Surg Br. 2008;90:1013
  12. Matsusue Y, Yamamuro T, Yoshii S, et al. Biodegradable screw fixation of rabbit tibia proximal osteotomies. J Appl Biomater. 1991;2:1
  13. Matsusue Y, Iida H, Kawanabe K, et al. Fixation of bone graft in total hip arthroplasty; disadvantage of sapphire screw and advantage of absorbable material. Seikeigeka. 1997;48:1104
  14. Matsusue Y, Hanafusa S, Yamamuro T, et al. Tissue reaction of bioabsorbable ultra high strength poly (l-lactide) rod. A long-term study in rabbits. Clin Orthop Relat Res. 1995;317:246
  15. Youm T, Maurer S, Stuchin S. Postoperative management after total hip and knee arthroplasty. J Arthroplasty. 2005;20:322
  16. Ishii S, Tamura J, Furukawa T, et al. Long-term study of high-strength hydroxyapatite/poly(l-lactide) composite rods for the internal fixation of bone fractures: a 2-4-year follow-up study in rabbits. J Biomed Mater Res B Appl Biomater. 2003;66:539
  17. Pihlajamäki H, Böstman O, Tynninen O, et al. Long-term tissue response to bioabsorbable poly-l-lactide and metallic screws: an experimental study. Bone. 2006;39:932
  18. Kwak J, Sim J, Kim S, et al. Delayed intra-articular inflammatory reaction due to poly-l-lactide bioabsorbable interference screw used in anterior cruciate ligament reconstruction. Arthroscopy. 2008;24:243
  19. Bergsma E, Rozema F, Bos R, et al. Foreign body reactions to resorbable poly(l-lactide) bone plates and screws used for the fixation of unstable zygomatic fractures. J Oral Maxillofac Surg. 1993;51:666
  20. Havelin L, Engesaeter L, Espehaug B, et al. The Norwegian Arthroplasty Register: 11 years and 73,000 arthroplasties. Acta Orthop Scand. 2000;71:337
  21. Mäkelä K, Eskelinen A, Pulkkinen P, et al. Cemented total hip replacement for primary osteoarthritis in patients aged 55 years or older: results of the 12 most common cemented implants followed for 25 years in the Finnish Arthroplasty Register. J Bone Joint Surg Br. 2008;90:1562
  22. Iida H, Matsusue Y, Kawanabe K, et al. Cemented total hip arthroplasty with acetabular bone graft for developmental dysplasia. Long-term results and survivorship analysis. J Bone Joint Surg Br. 2000;82:176

 No benefits or funds were received in support of the study.

PII: S0883-5403(09)00131-4

doi: 10.1016/j.arth.2009.04.030

The Journal of Arthroplasty
Volume 24, Issue 8 , Pages 1146-1151 , December 2009