« Previous
Next »
The Journal of Arthroplasty
Volume 25, Issue 5
, Pages 680-686
, August 2010
Comparison of Steady State Femoral Head Penetration Rates Between Two Highly Cross-Linked Polyethylenes in Total Hip Arthroplasty
References
- . The problem is osteolysis. Clin Orthop Relat Res. 1995;311:46
- . Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop Relat Res. 1999;363:135
- . Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. Clin Orthop Relat Res. 1990;258:95
- . The radiation improvement of polyethylene prostheses. A preliminary study. J Bone Joint Surg Br. 1978;60-B-3:370
- Study of retrieved acetabular sockets made from high-dose, cross-linked polyethylene. J Arthroplasty. 2001;16-8(Suppl 1):129
- Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls. Clin Orthop Relat Res. 1999;369:73
- Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res. 1999;17-2:157
- Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene. A hip-simulator study. J Bone Joint Surg Am. 2000;82-A-12:1708
- A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty. 2001;16-2:149
- . Bearing surfaces in total hip replacements: state of the art and future developments. In: Instr Course Lect. Vol. 50:2001;p. 165
- . A review of current cross-linked polyethylenes used in total joint arthroplasty. Clin Orthop Relat Res. 2005;430:46
- . The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. J Biomed Mater Res A. 2003;66-1:146
- Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. J Bone Joint Surg Am. 2004;86-A-6:1271
- Early failure due to osteolysis associated with contemporary highly cross-linked ultra-high molecular weight polyethylene. A case report. J Bone Joint Surg Am. 2004;86-A-5:1051
- Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty. J Bone Joint Surg Am. 2007;89-10:2212
- Evaluation of oxidation and fatigue damage of retrieved crossfire polyethylene acetabular cups. J Bone Joint Surg Am. 2007;89-9:2023
- Steady-state penetration rates of electron beam-irradiated, highly cross-linked polyethylene at an average 45-month follow-up. J Arthroplasty. 2006;21-7:935
- Five-year experience with Crossfire highly cross-linked polyethylene. Clin Orthop Relat Res. 2005;441:143
- The Otto Aufranc Award. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop Relat Res. 2004;429:6
- Clinical performance of a Durasul highly cross-linked polyethylene acetabular liner for total hip arthroplasty at five years. J Bone Joint Surg Am. 2005;87-8:1816
- A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners. J Arthroplasty. 2006;21-6(Suppl 2):17
- Short-term in vivo wear of cross-linked polyethylene. J Bone Joint Surg Am. 2004;86-A-4:748
- Correlation between early and late wear rates in total hip arthroplasty with application to the performance of marathon cross-linked polyethylene liners. J Arthroplasty. 2003;18-7(Suppl 1):60
- In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty. 2005;20-7:880
- . Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial. J Arthroplasty. 2003;18-7(Suppl 1):55
- In vivo wear and migration of highly cross-linked polyethylene cups a radiostereometry analysis study. J Arthroplasty. 2005;20-4:409
- A comparison of the penetration rate of two polyethylene acetabular liners of different levels of cross-linking. A prospective randomised trial. J Bone Joint Surg Br. 2007;89-11:1439
- 5-year experience of highly cross-linked polyethylene in cemented and uncemented sockets: Two randomized studies using radiostereometric analysis. Acta Orthop. 2007;78-6:746
- . Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79-11:1635
- Clinical performance of highly cross-linked polyethylenes in total hip arthroplasty. J Bone Joint Surg Am. 2007;89-12:2779
- Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2003;85-A-3:505
- Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg Am. 2003;85-A-6:1111
- Radiographic methods for the assessment of polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2005;87-10:2323
- . Amstutz HC. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17
- . Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20
- Radiographic evaluation of penetration by the femoral head into the polyethylene liner over time. J Bone Joint Surg Am. 1997;79-7:1040
- Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in. J Bone Joint Surg Am. 1999;81-6:821
- Effects of hip-loading input on simulated wear of Al2O3-PTFE materials. In: Wear 13th International Conference on Wear of Materials. 250:2001;p. 159
- . Longitudinal data analysis for discrete and continuous outcomes. Biometrics. 1986;42-1:121
- Comparison of femoral head penetration using RSA and the Martell method. Clin Orthop Relat Res. 2006;448:52
- Clinical experience with gamma irradiation-crosslinked polyethylene—a 14 to 20 year follow-up report. S Afr Bone Joint Surg. 1999;11:140
- . Wear of high-dose gamma-irradiated polyethylene in total hip replacements. J Orthop Sci. 2000;5-3:223
- . Low-friction arthroplasty of the hip using alumina ceramic and cross-linked polyethylene. A ten-year follow-up report. J Bone Joint Surg Br. 1999;81-1:54
- Ex vivo wear of conventional and cross-linked polyethylene acetabular liners. Clin Orthop Relat Res. 2005;438:158
- In vivo oxidation of retrieved cross-linked ultra-high-molecular-weight polyethylene acetabular components with residual free radicals. J Arthroplasty. 2006;21-7:1005
- The effect of real-time aging on the oxidation and wear of highly cross-linked UHMWPE acetabular liners. Biomaterials. 2006;27-9:1980
- Oxidative degradation in highly cross-linked and conventional polyethylene after 2 years of real-time shelf aging. Biomaterials. 2006;27-10:2275
- . Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene. J Biomed Mater Res. 1999;46-4:573
- The basis for a second-generation highly cross-linked UHMWPE. Clin Orthop Relat Res. 2006;453:265
- Wear resistance and mechanical properties of highly cross-linked, ultrahigh-molecular weight polyethylene doped with vitamin E. J Arthroplasty. 2006;21-4:580
- . Effect of cross-linking on the microstructure and mechanical properties of ultra-high molecular weight polyethylene. Clin Orthop Relat Res. 2005;440:149
- Highly cross-linked polyethylene in cemented THA: randomized study of 61 hips. Clin Orthop Relat Res. 2003;417:126
- Comparison of CT, MRI, and radiographs in assessing pelvic osteolysis: a cadaveric study. Clin Orthop Relat Res. 2005;437:138
- . A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty. 2002;17-5:649
- Incidence and volume of pelvic osteolysis at early follow-up with highly cross-linked and noncross-linked polyethylene. J Arthroplasty. 2007;22-6(Suppl 2):134
- Radiostereometric analysis comparison of wear of highly cross-linked polyethylene against 36- vs 28-mm femoral heads. J Arthroplasty. 2007;22-6(Suppl 2):125
- Large diameter femoral heads on highly cross-linked polyethylene: minimum 3-year results. Clin Orthop Relat Res. 2006;447:53
- Minimum 6-year follow-up of highly cross-linked polyethylene in THA. Clin Orthop Relat Res. 2007;465:122
No benefits or funds were received in support of the study.
PII: S0883-5403(09)00174-0
doi: 10.1016/j.arth.2009.05.006
« Previous
Next »
The Journal of Arthroplasty
Volume 25, Issue 5
, Pages 680-686
, August 2010
