The Journal of Arthroplasty
Volume 26, Issue 1 , Pages 58-64 , January 2011

Whole Blood Metal Ion Concentrations in Correlation With Activity Level in Three Different Metal-On-Metal Bearings

Received 17 March 2009 ,Accepted 15 November 2009.

References 

  1. Wiles P. The surgery of the osteoarthritic hip. Br J Surg. 1958;45:488
  2. Wroblewski BM, Taylor GW, Siney P. Low-friction arthroplasty: 19 to 25 year results. Orthopedics. 1992;15:42
  3. Gillespie WJ, Frampton CMA, Henderson RJ, et al. The incidence of cancer following total hip replacement. J Bone Joint Surg Br. 1988;70B:539
  4. August AC, Aldam CH, Pynsent PB. The McKee-Farrar hip arthroplasty. A long-term study. J Bone Joint Surg Br. 1986;68:520
  5. Jacobsson SA, Djerf K, Wahlstrom O. A comparative study between McKee-Farrar and Charnley arthroplasty with long-term follow-up periods. J Arthroplasty. 1990;5:9
  6. Schmalzried TP, Szuszczewicz ES, Akizuki KH, et al. Factors correlating with long term survival of McKee-Farrar total hip prostheses. Clin Orthop Relat Res. 1996;(329 Suppl):48
  7. McKellop H, Park SH, Chiesa R, et al. In vivo wear of three types of metal on metal hip prostheses during two decades of use. Clin Orthop Relat Res. 1996;(329 Suppl):S128
  8. Kothari M, Bartel DL, Booker JF. Surface geometry of retrieved McKee-Farrar total hip replacements. Clin Orthop Relat Res. 1996;(329 Suppl):S141
  9. Isaac GH, Thompson J, Williams S, et al. Metal-on-metal bearing surfaces: materials, manufacture, design, optimization, and alternatives. Proc Inst Mech Eng [H]. 2006;220:209
  10. Tipper JL, Firkins PJ, Ingham E, et al. Quantitative analysis of the wear and wear debris from low and high carbon content cobalt chrome alloys used in metal on metal hip replacements. J Mater Sci Mater Med. 1999;10:353
  11. Nevelos J, Shelton JC, Fisher J. Metallurgical considerations in the wear of metal-on-metal hip bearings. Hip International. 2004;14:1
  12. MacDonald SJ, McCalden RW, Chess DG, et al. Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res. 2003;282
  13. Jacobs JJ, Hallab NJ, Skipor AK. Metal degradation products: a cause for concern in metal-metal bearings. Clin Orthop Relat Res. 2003;139
  14. Visuri TI, Pukkala E, Pulkkinen P. Cancer incidence and causes of death among total hip replacement patients: a review based on Nordic cohorts with a special emphasis on metal-on-metal bearings. Proc Inst Mech Eng [H]. 2006;220:399
  15. Zahiri CA, Schmalzried TP, Szuszczewicz ES, et al. Assessing activity in joint replacement patients. J Arthroplasty. 1998;13:890
  16. Beaulé PE, Dorey F, LeDuff M, et al. Validation of the UCLA activity scale in the assessment of the clinical outcome of total hip arthroplasty. In: Presented at the Western Orthopaedic Association's 68th annual meeting San Francisco, CA. 2004;
  17. Harris H. Harris hip score. J Bone Joint Surg Am. 1969;51:737
  18. Merle d'Aubigne R. Functional results of arthroplasty of the hip. Acta Orthop Belg. 1953;19:81
  19. Jacobs JJ, Skipor AK, Campbell PA, et al. Can metal levels be used to monitor metal-on-metal hip arthroplasties. J Arthroplasty. 2004;19(8 Suppl 3):59
  20. De Haan R, Pattyn C, Gill HS, et al. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br. 2008;90:1291
  21. Heisel C, Streich N, Krachler M, et al. Characterization of the running-in period in total hip resurfacing arthroplasty: an in vivo and in vitro metal ion analysis. J Bone Joint Surg Am. 2008;90(Suppl 3):125
  22. Rieker CB, Schön R, Köttig P. Development and validation of a second-generation metal-on-metal bearing: laboratory studies and analysis of retrievals. J Arthroplasty. 2004;19:5
  23. Venditolli PA, Mottard S, Roy AG, et al. Chromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip. J Bone Joint Surg [Br]. 2007;89:441
  24. Affatato S, Spinelli M, Zavalloni M, et al. Predictive role of the lambda ratio in the evaluation of metal-on-metal total hip replacement. Proc Inst Mech Eng [H]. 2008;222:617
  25. Daniel J, Ziaee H, Salama A, et al. The effect of the diameter of metal-on-metal bearings on systemic exposure to cobalt and chromium. J Bone Joint Surg Br. 2006;88:443
  26. Heisel C, Silva M, Skipor AK, et al. The relationship between activity and ions in patients with metal-on-metal bearing hip prostheses. J Bone Joint Surg [Am]. 2005;87-A:781
  27. Khan M, Takahashi T, Kuiper JH, et al. Current in vivo wear of metal-on-metal bearings assessed by exercise-related rise in plasma cobalt level. J Orthop Res. 2006;24:2029
  28. Brodner W, Grübl A, Jankovsky R, et al. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty. 2004;19(8 Suppl 3):66

 No benefits or funds were received in support of the study.

PII: S0883-5403(09)00543-9

doi: 10.1016/j.arth.2009.11.007

The Journal of Arthroplasty
Volume 26, Issue 1 , Pages 58-64 , January 2011