« Previous
Next »
The Journal of Arthroplasty
Volume 26, Issue 3
, Pages 346-353
, April 2011
Human Knee Joint Anatomy Revisited: Morphometry in the Light of Sex-Specific Total Knee Arthroplasty
References
- . The need for gender-specific prostheses in TKA: does size make a difference?. Orthopedics. 2006;29-S:53
- . The gender-specific (female) knee. Orthopedics. 2006;29:768
- Intra-operative measurements of male and female distal femurs during primary total knee arthroplasty. J Knee Surg. 2002;15:213
- . The female knee: anatomic variations. J Am Acad Orthop Surg. 2007;15-S1:31
- . Gender-specific design in total knee arthroplasty. J Arthroplasty. 2007;22:27
- . Early experience with a new total knee implant: maximizing range of motion and function with gender-specific sizing. Surg Technol Int. 2007;16:199
- The female knee: anatomic variations and the female-specific total knee design. Clin Orthop Relat Res. 2008;466:3059
- Gender-specific total knee replacement: prospectively collected clinical outcomes. Clin Orthop Relat Res. 2008;466:2612
- . A correlative study of the geometry and anatomy of the distal femur. Clin Orthop. 1990;260:98
- Geometry and motion of the knee for implant and orthotic design. J Biomech. 1985;18:487
- . Knee morphology as a guide to knee replacement. Clin Orthop Rel Res. 1975;112:231
- Dimensions of the knee: Radiographic and autopsy study of sizes required for a knee prosthesis. Ann Rheum Dis. 1972;31:54
- . The anatomy and functional axis of the femur. J Bone Joint Surg Am. 1987;69:873
- . A study of knee geometry applied to the design of condylar prostheses. Biomed Eng. 1974;9:14
- Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems. J Bone Joint Surg Am. 2003;85-S4:115
- Rotational landmarks and sizing of the distal femur in total knee arthroplasty. Clin Orthop Rel Res. 1996;331:35
- Effects of increasing tibial slope on the biomechanics of the knee. Am J Sports Med. 2004;32:376
- Computer-assisted planning and robot-assisted surgery in anterior cruciate ligament reconstruction. Oper Tech Orthop. 2000;10:50
- . Tibiofemoral movement 1: the shapes and relative movements of the femur and the tibia in the unloaded cadaver knee. J Bone Joint Surg Br. 2000;82:1189
- Does the femur roll-back with flexion?. J Bone Joint Surg Br. 2004;86:925
- Effect of femoral condyle configuration on disability after an anterior cruciate ligament rupture. Acta Orthop Scand. 1993;64:571
- Side differences of knee joint cartilage volume, thickness, and surface area, and correlation with lower limb dominance—an MRI-based study. Osteoarthritis Cartilage. 2002;10:914
- Randomized controlled trial of cemented versus cementless press-fit condylar total knee replacement: 15-year survival analysis. J Bone Joint Surg Br. 2007;89:1608
- Factors influencing wear and osteolysis in press-fit condylar modular total knee replacements. Clin Orthop Relat Res. 2004;428:40
- Survival of the AGC total knee arthroplasty is similar for arthrosis and rheumatoid arthritis: Finnish Arthroplasty Register report on 8,467 operations carried out between 1985 and 1999. Acta Orthop. 2005;76:85
- . Survivorship analysis of total knee arthroplasty: cumulative rates of survival of 9,200 total knee arthroplasties. J Bone Joint Surg Am. 1991;73:397
- Factors affecting the durability of primary total knee prostheses. J Bone Joint Surg Am. 2003;85:259
- . A 15-year follow-up study of 4,606 primary total knee replacements. J Bone Joint Surg Br. 2007;89:1452
- The Swedish Knee Arthroplasty Register 1975-1997: an update with special emphasis on 41,223 knees operated on in 1988-1997. Acta Orthop Scand. 2001;72:503
- . Restoration of femoral anatomy in TKA with unisex and gender-specific components. Clin Orthop Relat Res. 2008;466:2711
- . The estimation of stature on the basis of measurements of the femur. Forensic Sci Int. 2005;147:185
- . Symmetry of the femoral notch width index. Am J Sports Med. 1997;25:687
- . Men and women have similar Q angles. J Bone Joint Surg Br. 2005;87:1498–1501
- . The effect of patellar thickness on intraoperative knee flexion and patellar tracking in total knee arthroplasty. J Arthroplasty. 2006;21:650
- . Morphometrical measurements of resected surface of femurs in Chinese knees: correlation to the sizing of current femoral implants. Knee. 2006;13:12
No benefits or funds were received in support of the study.
PII: S0883-5403(10)00007-0
doi: 10.1016/j.arth.2009.12.019
© 2011 Elsevier Inc. All rights reserved.
« Previous
Next »
The Journal of Arthroplasty
Volume 26, Issue 3
, Pages 346-353
, April 2011
