The Journal of Arthroplasty
Volume 27, Issue 2 , Pages 324.e1-324.e4, February 2012

Metal Transfer on a Ceramic Head With a Single Rim Contact

  • Ivan M. Tomek, MD

      Affiliations

    • Dartmouth Hitchcock Medical Center, Hanover, New Hampshire
  • ,
  • John H. Currier, MS

      Affiliations

    • Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
    • Corresponding Author InformationReprint requests: John H. Currier, MS, Thayer School of Engineering, 8000 Cummings, Hanover, NH 03755.
  • ,
  • Michael B. Mayor, MD

      Affiliations

    • Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire
    • Dartmouth Medical School, Dartmouth College, Hanover, New Hampshire
  • ,
  • Douglas W. Van Citters, PhD

      Affiliations

    • Thayer School of Engineering, Dartmouth College, Hanover, New Hampshire

Received 17 September 2010; accepted 12 February 2011. published online 28 March 2011.

Abstract 

A notable feature of retrieved ceramic-on-ceramic hips is metal transfer on the femoral head, which is an important alteration of the bearing surface. This report documents metal transfer streaks on a ceramic femoral head resulting from discrete subluxations, which occurred intraoperatively during reduction and stability testing. An important implication is that metal transfer can occur whenever a femoral head is reduced into the liner during surgery or from in vivo subluxation/dislocation. If a ceramic liner is recessed below a raised metal rim, care should be taken to prevent head-to-rim contact during intraoperative reductions and stability testing. If metal transfer occurs during final surgical reduction of the hip, its presence may remain undetected, and detrimental effects are present from the time of surgery.

Keywords: metal transfer, ceramic hip, ceramic-on-ceramic, hip surgery, hip dislocation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 The Conflict of Interest statement associated with this article can be found at doi:10.1016/j.arth.2011.02.025.

PII: S0883-5403(11)00070-2

doi:10.1016/j.arth.2011.02.025

The Journal of Arthroplasty
Volume 27, Issue 2 , Pages 324.e1-324.e4, February 2012