Advertisement
Research Article| Volume 27, ISSUE 8, P1429-1436, September 2012

Influence of Electron Beam Melting Manufactured Implants on Ingrowth and Shear Strength in an Ovine Model

Published:April 13, 2012DOI:https://doi.org/10.1016/j.arth.2012.02.025

      Abstract

      Arthroplasty has evolved with the application of electron beam melting (EBM) in the manufacture of porous mediums for uncemented fixation. Osseointegration of EBM and plasma-sprayed titanium (Ti PS) implant dowels in adult sheep was assessed in graduated cancellous defects and under line-to-line fit in cortical bone. Shear strength and bony ingrowth (EBM) and ongrowth (Ti PS) were assessed after 4 and 12 weeks. Shear strength of EBM exceeded that for Ti PS at 12 weeks (P = .030). Ongrowth achieved by Ti PS in graduated cancellous defects followed a distinctive pattern that correlated to progressively decreasing radial distances between defect and implant, whereas cancellous ingrowth values at 12 weeks for the EBM were not different. Osteoconductive porous structures manufactured using EBM present a viable alternative to traditional surface treatments.

      Keywords

      To read this article in full you will need to make a payment

      Purchase one-time access:

      Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online access
      One-time access price info
      • For academic or personal research use, select 'Academic and Personal'
      • For corporate R&D use, select 'Corporate R&D Professionals'

      Subscribe:

      Subscribe to The Journal of Arthroplasty
      Already a print subscriber? Claim online access
      Already an online subscriber? Sign in
      Institutional Access: Sign in to ScienceDirect

      References

        • Ryan G.
        • Pandit A.
        • Apatsidis D.P.
        Fabrication methods of porous metals for use in orthopaedic applications.
        Biomaterials. 2006; 27: 2651
        • Heinl P.
        • Muller L.
        • Korner C.
        • et al.
        Cellular Ti-6Al-4V structures with interconnected macro porosity for bone implants fabricated by selective electron beam melting.
        Acta Biomaterialia. 2008; 4: 1536
        • Li X.
        • Wang C.T.
        • Zhang W.G.
        • et al.
        Properties of a porous Ti-6Al-4V implant with a low stiffness for biomedical application.
        Proc Inst Mechan Eng Part H-J Eng Med. 2009; 223: 173
        • Marin E.
        • Fusi S.
        • Pressacco M.
        • et al.
        Characterization of cellular solids in Ti6Al4V for orthopaedic implant applications: trabecular titanium.
        J Mechanic Behav Biomed Mater. 2010; 3: 373
        • Murr L.E.
        • Gaytan S.M.
        • Medina F.
        • et al.
        Next-generation biomedical implants using additive manufacturing of complex, cellular and functional mesh arrays.
        Philos Trans Royal Soc London, Series a (Mathematical, Physical & Engineering Sciences). 2010; 368: 1999
        • Murr L.E.
        • Quinones S.A.
        • Gaytan S.M.
        • et al.
        Microstructure and mechanical behavior of Ti-6Al-4V produced by rapid-layer manufacturing, for biomedical applications.
        J Mechan Behav Biomed Mater. 2009; 2: 20
        • Ponader S.
        • Vairaktaris E.
        • Heinl P.
        • et al.
        Effects of topographical surface modifications of electron beam melted Ti-6Al-4V titanium on human fetal osteoblasts.
        J Biomed Mater Res Part A. 2008; 84: 1111
        • Ponader S.
        • von Wilmowsky C.
        • Widenmayer M.
        • et al.
        In vivo performance of selective electron beam–melted Ti-6Al-4V structures.
        J Biomed Mater Res Part A. 2010; 92: 56
        • Murr L.E.
        • Amato K.N.
        • Li S.J.
        • et al.
        Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting.
        J Mech Behav Biomed Mater. 2011; 4: 1396
        • Parthasarathy J.
        • Starly B.
        • Raman S.
        • et al.
        Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM).
        J Mechan Behav of Biomed Mater. 2010; 3: 249
        • Thomsen P.
        • Malmstrom J.
        • Emanuelsson L.
        • et al.
        Electron beam-melted, free-form-fabricated titanium alloy implants: material surface characterization and early bone response in rabbits.
        J Biomed Mater Res B Appl Biomater. 2009; 90: 35
        • Svehla M.
        • Morberg P.
        • Bruce W.
        • et al.
        No effect of a type I collagen gel coating in uncemented implant fixation.
        J Biomed Mater Res Part B, Appl Biomater. 2005; 74: 423
        • Svehla M.
        • Morberg P.
        • Bruce W.
        • et al.
        The effect of substrate roughness and hydroxyapatite coating thickness on implant shear strength.
        J Arthroplasty. 2002; 17: 304
        • Svehla M.
        • Morberg P.
        • Zicat B.
        • et al.
        Morphometric and mechanical evaluation of titanium implant integration: comparison of five surface structures.
        J Biomed Mater Res. 2000; 51: 15
        • Chen D.
        • Bertollo N.
        • Lau A.
        • et al.
        Osseointegration of porous titanium implants with and without electrochemically deposited DCPD coating in an ovine model.
        J Orthop Surg Res. 2011; 6
        • Bertollo N.
        • Matsubara M.
        • Shinodo T.
        • et al.
        Effect of surgical fit on integration of cancellous bone and implant cortical bone shear strength for a porous titanium.
        J Arthroplasty. 2011; 26: 1000
        • Dhert W.J.
        • Verheyen C.C.
        • Braak L.H.
        • et al.
        A finite element analysis of the push-out test: influence of test conditions.
        J Biomed Mater Res. 1992; 26: 119
        • Kold S.
        • Rahbek O.
        • Zippor B.
        • et al.
        Bone compaction enhances fixation of hydroxyapatite-coated implants in a canine gap model.
        J Biomed Mater Res Part B, Appl Biomater. 2005; 75: 49
        • Biemond J.E.
        • Aquarius R.
        • Verdonschot N.
        • et al.
        Frictional and bone ingrowth properties of engineered surface topographies produced by electron beam technology.
        Arch Orthop Trauma Surg. 2011; 131: 711
        • Bobyn J.D.
        • Stackpool G.J.
        • Hacking S.A.
        • et al.
        Characteristics of bone ingrowth and interface mechanics of a new porous tantalum biomaterial.
        J Bone Joint Surg Br. 1999; 81: 907
        • Bobyn J.D.
        • Toh K.K.
        • Hacking S.A.
        • et al.
        Tissue response to porous tantalum acetabular cups: a canine model.
        J Arthroplasty. 1999; 14: 347